Messages in this thread | | | From | Geert Uytterhoeven <> | Date | Wed, 13 Mar 2019 11:30:24 +0100 | Subject | Re: [PATCH] um: define set_pte_at() as a static inline function, not a macro |
| |
On Wed, Mar 13, 2019 at 11:16 AM Bartosz Golaszewski <brgl@bgdev.pl> wrote: > From: Bartosz Golaszewski <bgolaszewski@baylibre.com> > > When defined as macro, the mm argument is unused and subsequently the > variable passed as mm is considered unused by the compiler. This fixes > a build warning. > > Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
Reviewed-by: Geert Uytterhoeven <geert@linux-m68k.org>
Gr{oetje,eeting}s,
Geert
-- Geert Uytterhoeven -- There's lots of Linux beyond ia32 -- geert@linux-m68k.org