Messages in this thread | | | From | Otavio Salvador <> | Date | Mon, 4 Feb 2019 21:15:13 -0200 | Subject | Re: [PATCH] regulator: rk808: Convert rk805 buck1/2 to use linear range |
| |
On Mon, Feb 4, 2019 at 5:10 AM Axel Lin <axel.lin@ingics.com> wrote: > > It looks like linear range is suitable to describe the voltage table > for rk805 buck1/2: > > selector 0 ~ 59: 0.7125V with uV_step = 12500 > selector 60 ~ 62: 1.8V with uV_step = 200000 > selector 63: 2.3V > > With this change, then rk805 buck1/2 can reuse rk808_reg_ops_ranges. > > Signed-off-by: Axel Lin <axel.lin@ingics.com>
Cool! Thanks for looking at that!
Tested-by: Otavio Salvador <otavio@ossystems.com.br>
-- Otavio Salvador O.S. Systems http://www.ossystems.com.br http://code.ossystems.com.br Mobile: +55 (53) 9 9981-7854 Mobile: +1 (347) 903-9750
| |