lkml.org 
[lkml]   [2019]   [Feb]   [3]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
Patch in this message
/
From
Date
Subject[PATCH 3.16 258/305] mmc: core: use mrq->sbc when sending CMD23 for RPMB
3.16.63-rc1 review patch.  If anyone has any objections, please let me know.

------------------

From: Wolfram Sang <wsa+renesas@sang-engineering.com>

commit a44f7cb937321d4961bfc8f28912126b06e701c5 upstream.

When sending out CMD23 in the blk preparation, the comment there
rightfully says:

* However, it is not sufficient to just send CMD23,
* and avoid the final CMD12, as on an error condition
* CMD12 (stop) needs to be sent anyway. This, coupled
* with Auto-CMD23 enhancements provided by some
* hosts, means that the complexity of dealing
* with this is best left to the host. If CMD23 is
* supported by card and host, we'll fill sbc in and let
* the host deal with handling it correctly.

Let's do this behaviour for RPMB as well, and not send CMD23
independently. Otherwise IP cores (like Renesas SDHI) may timeout
because of automatic CMD23/CMD12 handling.

Reported-by: Masaharu Hayakawa <masaharu.hayakawa.ry@renesas.com>
Signed-off-by: Wolfram Sang <wsa+renesas@sang-engineering.com>
Tested-by: Clément Péron <peron.clem@gmail.com>
Reviewed-by: Avri Altman <avri.altman@wdc.com>
Reviewed-by: Niklas Söderlund <niklas.soderlund+renesas@ragnatech.se>
Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
[bwh: Backported to 3.16: adjust context]
Signed-off-by: Ben Hutchings <ben@decadent.org.uk>
---
drivers/mmc/card/block.c | 15 ++++++++++-----
1 file changed, 10 insertions(+), 5 deletions(-)

--- a/drivers/mmc/card/block.c
+++ b/drivers/mmc/card/block.c
@@ -449,7 +449,7 @@ static int mmc_blk_ioctl_cmd(struct bloc
struct mmc_blk_ioc_data *idata;
struct mmc_blk_data *md;
struct mmc_card *card;
- struct mmc_command cmd = {0};
+ struct mmc_command cmd = {}, sbc = {};
struct mmc_data data = {0};
struct mmc_request mrq = {NULL};
struct scatterlist sg;
@@ -539,10 +539,15 @@ static int mmc_blk_ioctl_cmd(struct bloc
}

if (is_rpmb) {
- err = mmc_set_blockcount(card, data.blocks,
- idata->ic.write_flag & (1 << 31));
- if (err)
- goto cmd_rel_host;
+ sbc.opcode = MMC_SET_BLOCK_COUNT;
+ /*
+ * We don't do any blockcount validation because the max size
+ * may be increased by a future standard. We just copy the
+ * 'Reliable Write' bit here.
+ */
+ sbc.arg = data.blocks | (idata->ic.write_flag & BIT(31));
+ sbc.flags = MMC_RSP_R1 | MMC_CMD_AC;
+ mrq.sbc = &sbc;
}

if ((MMC_EXTRACT_INDEX_FROM_ARG(cmd.arg) == EXT_CSD_SANITIZE_START) &&
\
 
 \ /
  Last update: 2019-02-03 14:56    [W:0.991 / U:0.052 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site