SubjectRe: [PATCH][next] scsi: pm80xx: fix logic to break out of loop when register value is 2 or 3
From
Date

Colin,

> The condition (reg_val != 2) || (reg_val != 3) will always be true
> because reg_val cannot be equal to two different values at the same
> time. Fix this by replacing the || operator with && so that the loop
> will loop if reg_val is not a 2 and not a 3 as was originally
> intended.

Applied to 5.5/scsi-queue, thanks!

--
Martin K. Petersen Oracle Linux Engineering

\
 
 \ /
  Last update: 2019-11-27 03:31    [W:0.062 / U:0.060 seconds]