Hi Andrew,
On Fri, Aug 31, 2018 at 04:18:51PM +0200, Andrew Lunn wrote: > > @@ -4691,6 +4685,9 @@ static int mvpp2_port_probe(struct platform_device *pdev, > > if (fwnode_property_read_bool(port_fwnode, "marvell,loopback")) > > port->flags |= MVPP2_F_LOOPBACK; > > > > + if (fwnode_property_present(port_fwnode, "fixed-link")) > > + port->flags |= MVPP2_F_FIXED_LINK; > > + > > There is no need to go look in device tree. When phylink calls > mac_config() it passes mode == MLO_AN_FIXED, when it is using a fixed > link.
Sure. This was a proposal to have a workaround when phylink does not call link_up(), so that we know which mode to pass to the function.
In the meantime Russell explained an assumption about the carrier link state made by phylink, and a proposal to avoid doing this kind of hack in the driver. I'll test his solution which will probably means we can drop this piece of code.
Thanks! Antoine
-- Antoine Ténart, Bootlin Embedded Linux and Kernel engineering https://bootlin.com
| |