SubjectRe: [RFC PATCH 1/2] dt-bindings: pwm: imx: Allow switching PWM output between PWM and GPIO
Lukasz Majewski <lukma@denx.de> wrote:

> Hi Michal,
>
> > Output of the PWM block of i.MX SoCs is always zero volts when the
> > block is disabled. This can caue issues when inverted PWM polarity is
> > needed. With inverted polarity a duty cycle = 0% corresponds to solid
> > high level on the output. If the PWM is dissabled its output
> > instantly goes to solid zero which corresponds to duty cycle = 100%.
> >
> > To have a trully inverted PWM output configure the PWM pad as a GPIO
> > with pull-up. Then switch the pad to PWM output whenever non-zero
> > duty cycle is needed.
>
> Just to ask - Is your display equipped with power supply enable/disable
> pin?
>
> As fair as I remember the trick to avoid flickering the display
> was to disable the display (enable-gpio property) and set the PWM PIN
> as GPIO to high in u-boot.
>
Unfortunately there are both types of displays. Some with an ENABLE
pin, some without.


Lothar Waßmann
--
___________________________________________________________

Ka-Ro electronics GmbH | Pascalstraße 22 | D - 52076 Aachen
Phone: +49 2408 1402-0 | Fax: +49 2408 1402-10
Geschäftsführer: Matthias Kaussen
Handelsregistereintrag: Amtsgericht Aachen, HRB 4996

www.karo-electronics.de | info@karo-electronics.de