Messages in this thread | | | Date | Wed, 1 Aug 2018 02:49:03 -0500 | From | Segher Boessenkool <> | Subject | Re: [PATCH v3 5/9] powerpc/traps: Print signal name for unhandled signals |
| |
On Wed, Aug 01, 2018 at 12:03:50AM -0700, Joe Perches wrote: > On Wed, 2018-08-01 at 08:37 +0200, Christophe LEROY wrote: > > Le 31/07/2018 à 16:50, Murilo Opsfelder Araujo a écrit : > > I would suggest to instead use a function like this: > > > > static const char *signame(int signr) > > { > > if (signr == SIGBUS) > > return "bus error"; > > if (signr == SIGFPE) > > return "floating point exception"; > > if (signr == SIGILL) > > return "illegal instruction"; > > if (signr == SIGILL) > > return "segfault"; > > if (signr == SIGTRAP) > > return "unhandled trap"; > > return "unknown signal"; > > } > > trivia: > > Unless the if tests are ordered most to least likely, > perhaps it would be better to use a switch/case and > let the compiler decide.
That would also show there are two entries for SIGILL (here and in the original patch), one of them very wrong.
Check the table with psignal or something?