lkml.org 
[lkml]   [2018]   [Jul]   [21]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH v4] iio: chemical: Add support for Bosch BME680 sensor
On Sat, Jul 21, 2018 at 06:43:51PM +0300, Andy Shevchenko wrote:
> On Sat, Jul 21, 2018 at 6:36 PM, Himanshu Jha
> <himanshujha199640@gmail.com> wrote:
>
> >> > + /* Look up table 1 for the possible gas range values */
> >> > + u32 lookupTable1[16] = {2147483647u, 2147483647u, 2147483647u,
> >> > + 2147483647u, 2147483647u, 2126008810u,
> >> > + 2147483647u, 2130303777u, 2147483647u,
> >> > + 2147483647u, 2143188679u, 2136746228u,
> >> > + 2147483647u, 2126008810u, 2147483647u,
> >> > + 2147483647u};
>
> This one needs perhaps a bit of though, but...
>
> >> > + /* Look up table 2 for the possible gas range values */
> >> > + u32 lookupTable2[16] = {4096000000u, 2048000000u, 1024000000u,
> >> > + 512000000u, 255744255u, 127110228u, 64000000u,
> >> > + 32258064u, 16016016u, 8000000u, 4000000u,
> >> > + 2000000u, 1000000u, 500000u, 250000u, 125000u};
>
> ...this one obviously just a not needed one. You may replace it with a
> one constant and simple calculation to get either value (index from
> value, or value from index).

Not sure to understand your opinion!?

Anything related to increase to .ro segment ?

I think adding is better to let compiler optimise the code a bit
further.

> --
> With Best Regards,
> Andy Shevchenko

--
Himanshu Jha
Undergraduate Student
Department of Electronics & Communication
Guru Tegh Bahadur Institute of Technology

\
 
 \ /
  Last update: 2018-07-21 17:53    [W:0.059 / U:0.876 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site