Messages in this thread | | | Date | Wed, 23 May 2018 15:29:15 -0700 | From | Guenter Roeck <> | Subject | Re: [PATCH v2 2/6] Documentation: DT: Add optional 'timeout-sec' property for sp805 |
| |
On Wed, May 23, 2018 at 01:32:03PM -0700, Ray Jui wrote: > Update the SP805 binding document to add optional 'timeout-sec' > devicetree property > > Signed-off-by: Ray Jui <ray.jui@broadcom.com> > Reviewed-by: Scott Branden <scott.branden@broadcom.com> > Reviewed-by: Guenter Roeck <linux@roeck-us.net> > --- > Documentation/devicetree/bindings/watchdog/arm,sp805.txt | 2 ++ > 1 file changed, 2 insertions(+) > > diff --git a/Documentation/devicetree/bindings/watchdog/arm,sp805.txt b/Documentation/devicetree/bindings/watchdog/arm,sp805.txt > index de93a4d..9cd7470 100644 > --- a/Documentation/devicetree/bindings/watchdog/arm,sp805.txt > +++ b/Documentation/devicetree/bindings/watchdog/arm,sp805.txt > @@ -18,6 +18,8 @@ Required properties: > > Optional properties: > - interrupts : Should specify WDT interrupt number. > +timeout-sec : Should specify default WDT timeout in seconds. If unset, the > + default timeout in the driver is 30 seconds
That looks odd, with the changed indentation and the missing '-' in front of 'timeout-sec'.
Guenter
| |