On Monday, April 16, 2018 02:06:41 PM Daniel Lezcano wrote:
> On 16/04/2018 12:11, Bartlomiej Zolnierkiewicz wrote:
> > From: Marek Szyprowski <m.szyprowski@samsung.com>
> >
> > When thermal sensor is not yet enabled, reading temperature might return
> > random value. This might even result in stopping system booting when such
> > temperature is higher than the critical value. Fix this by checking if TMU
> > has been actually enabled before reading the temperature.
> >
> > This change fixes booting of Exynos4210-based board with TMU enabled (for
> > example Samsung Trats board), which was broken since v4.4 kernel release.
>
> Why not move the thermal_zone_of_sensor_register *after* initializing
> the sensor ?

For initializing the sensor we need data obtained from
therm_zone_of_sensor_register() so it cannot be easily
done (especially since we also want the fix to be
ported to -stable kernels). For more detailed description
please see:

https://lkml.org/lkml/2018/4/10/376

> > Signed-off-by: Marek Szyprowski <m.szyprowski@samsung.com>
> > Fixes: 9e4249b40340 ("thermal: exynos: Fix first temperature read after registering sensor")
> > CC: stable@vger.kernel.org # v4.6+
> > Signed-off-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com>

Best regards,
--
Bartlomiej Zolnierkiewicz
Samsung R&D Institute Poland
Samsung Electronics

\
 
 \ /
  Last update: 2018-04-16 14:19    [W:0.067 / U:1.392 seconds]