From
Subject[PATCH v3 4/7] watchdog: pnx4008: make use of timeout-secs provided in devicetree
Date
watchdog_init_timeout() will allways pick timeout_param since it
defaults to a valid timeout.

Following best practice described in
Documentation/watchdog/watchdog-kernel-api.txt to make use of
the parameter logic.

Signed-off-by: Marcus Folkesson <marcus.folkesson@gmail.com>
Reviewed-by: Guenter Roeck <linux@roeck-us.net>
---
drivers/watchdog/pnx4008_wdt.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/watchdog/pnx4008_wdt.c b/drivers/watchdog/pnx4008_wdt.c
index 0529aed158a4..8e261799c84e 100644
--- a/drivers/watchdog/pnx4008_wdt.c
+++ b/drivers/watchdog/pnx4008_wdt.c
@@ -78,7 +78,7 @@
#define WDOG_COUNTER_RATE 13000000 /*the counter clock is 13 MHz fixed */

static bool nowayout = WATCHDOG_NOWAYOUT;
-static unsigned int heartbeat = DEFAULT_HEARTBEAT;
+static unsigned int heartbeat;

static DEFINE_SPINLOCK(io_lock);
static void __iomem *wdt_base;
--