lkml.org 
[lkml]   [2018]   [Nov]   [3]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
From
Date
SubjectRe: [PATCH v3 2/3] staging: iio: ad7780: update voltage on read
On Thu, 1 Nov 2018 15:20:55 +0000
"Ardelean, Alexandru" <alexandru.Ardelean@analog.com> wrote:
>
> This looks wrong.
> I admit this was done in the same way in the probe function, but that looks
> a bit wrong as well.
>
> Typically, the return value of `regulator_get_voltage()` would get checked
> with:
>
> ret = regulator_get_voltage(st->reg);
> if (ret < 0)
> return ret;
> *val = ret / 1000;
>
> So, negative values are errors and zero & positive values are valid voltage
> values.

I see. So -EINVAL is only used when sent the wrong info type?

\
 
 \ /
  Last update: 2018-11-03 17:06    [W:0.118 / U:0.064 seconds]