On Mon, Oct 29, 2018 at 11:45:04AM +0100, Daniel Aberger - Profihost AG wrote:

...

> [Mi Aug 22 13:54:47 2018] mce: [Hardware Error]: CPU 15: Machine Check:
> 0 Bank 7: cc00008000010091
> [Mi Aug 22 13:54:47 2018] mce: [Hardware Error]: TSC 0 ADDR 70fb1b3ec0
> MISC 142189886
> [Mi Aug 22 13:54:47 2018] mce: [Hardware Error]: PROCESSOR 0:306f2 TIME
> 1534938887 SOCKET 1 APIC 26 microcode 3d

The fact that you see this, means, the error has reached the last
notifier. So the EDAC notifier must've run too and handed the error to
the EDAC driver.

Can you send a full dmesg from that machine, privately to Tony and me is
fine too.

Thx.

--
Regards/Gruss,
Boris.

Good mailing practices for 400: avoid top-posting and trim the reply.

\
 
 \ /