Messages in this thread | | | From | Feng Li <> | Date | Fri, 19 Oct 2018 16:02:08 +0800 | Subject | Re: [PATCH] smartpqi: Fix timeout of smartpqi probe stage |
| |
Just Ping. This is a very serious issue. The OS boot from this raid controller couldn't find bock devices after installing OS.
I think this patch should be merged asap.
Feng Li <lifeng1519@gmail.com> 于2018年10月12日周五 上午11:13写道: > > I use 'HPE Smart Array E208i-a SR Gen10 Controller', and pass through > the SAS controller from ESXi 6.0U1 to VM, which is installed CentOS 7.4/7.5. > The disk is not found. > > The error log is "controller not ready after 30 seconds." > > Add some logs, and could check the probe stage needs nearly 36s to match the > status. > > Signed-off-by: Li Feng <fengli@smartx.com> > --- > drivers/scsi/smartpqi/smartpqi_sis.c | 2 +- > 1 file changed, 1 insertion(+), 1 deletion(-) > > diff --git a/drivers/scsi/smartpqi/smartpqi_sis.c > b/drivers/scsi/smartpqi/smartpqi_sis.c > index 5141bd4c9..bc7efdacb 100644 > --- a/drivers/scsi/smartpqi/smartpqi_sis.c > +++ b/drivers/scsi/smartpqi/smartpqi_sis.c > @@ -59,7 +59,7 @@ > > #define SIS_CTRL_KERNEL_UP 0x80 > #define SIS_CTRL_KERNEL_PANIC 0x100 > -#define SIS_CTRL_READY_TIMEOUT_SECS 30 > +#define SIS_CTRL_READY_TIMEOUT_SECS 90 > #define SIS_CTRL_READY_RESUME_TIMEOUT_SECS 90 > #define SIS_CTRL_READY_POLL_INTERVAL_MSECS 10 > > -- > 2.11.0
-- Thanks and Best Regards, Feng Li(Alex)
| |