SubjectRe: [PATCH] xen: don't print error message in case of missing Xenstore entry
From
Date
On 30/05/17 15:25, Boris Ostrovsky wrote:
> On 05/29/2017 05:13 AM, Juergen Gross wrote:
>> When registering for the Xenstore watch of the node control/sysrq the
>> handler will be called at once. Don't issue an error message if the
>> Xenstore node isn't there, as it will be created only when an event
>> is being triggered.
>>
>> Signed-off-by: Juergen Gross <jgross@suse.com>
>> ---
>> drivers/xen/manage.c | 7 +++++--
>> 1 file changed, 5 insertions(+), 2 deletions(-)
>>
>> diff --git a/drivers/xen/manage.c b/drivers/xen/manage.c
>> index c1ec8ee80924..7ddd0803da23 100644
>> --- a/drivers/xen/manage.c
>> +++ b/drivers/xen/manage.c
>> @@ -277,8 +277,11 @@ static void sysrq_handler(struct xenbus_watch *watch, const char *path,
>> err = xenbus_transaction_start(&xbt);
>> if (err)
>> return;
>> - if (xenbus_scanf(xbt, "control", "sysrq", "%c", &sysrq_key) < 0) {
>> - pr_err("Unable to read sysrq code in control/sysrq\n");
>> + err = xenbus_scanf(xbt, "control", "sysrq", "%c", &sysrq_key);
>> + if (err < 0) {
>> + if (err != -ENOENT)
>
> Can we distinguish initialization invocation from actual watch firing?
> E.g. '|| (system_state >= SYSTEM_RUNNING)'?

The watch will fire again after suspend/resume (e.g. live migration).


Juergen

>
> -boris
>
>> + pr_err("Error %d reading sysrq code in control/sysrq\n",
>> + err);
>> xenbus_transaction_end(xbt, 1);
>> return;
>> }
>
>

\
 
 \ /