SubjectRe: [PATCH v3 3/4] hwmon: (adt7475) temperature smoothing
From
Date
On 05/14/2017 02:23 PM, Chris Packham wrote:
> On 15/05/17 03:40, Guenter Roeck wrote:
>> On 05/10/2017 08:45 PM, Chris Packham wrote:
>>> When enabled temperature smoothing allows ramping the fan speed over a
>>> configurable period of time instead of jumping to the new speed
>>> instantaneously.
>>>
>>> Signed-off-by: Chris Packham <chris.packham@alliedtelesis.co.nz>
>>> ---
>>>
>>> Changes in v2:
>>> - use a single tempN_smoothing attribute
>>
>> This is a bit confusing. tempN suggests that the attribute would be associated
>> with a given temperature, not with fan control. Not that I have a better idea
>> for an attribute name, though, so unless you find a better name I am ok with it.
>>
>
> The datasheet is a bit confusing in this respect.
>
> From the description of register 0x62:
>
> "Assuming that PWMx is associated with the Remote 1 temperature channel,
> these bits define the maximum rate of change of the PWMx output for
> Remote 1 temperature related changes. Instead of the fan speed jumping
> instantaneously to its newly determined speed, it ramps
> gracefully at the rate determined by these bits. This feature ultimately
> enhances the acoustics of the fan."
>
> Based on my reading it's a property of the temperature input not of the
> PWM. If you changed pwmN_auto_channels_temp this setting would stay with
> the temperature sensor not the PWM.
>

Agreed, that is why I said that I don't have a better idea ...

Guenter

\
 
 \ /