Messages in this thread | | | Date | Mon, 24 Apr 2017 10:51:09 +0200 | From | Maxime Ripard <> | Subject | Re: [PATCH v5 02/11] clk: sunxi-ng: add support for DE2 CCU |
| |
Hi,
On Sun, Apr 23, 2017 at 06:37:45PM +0800, Icenowy Zheng wrote: > +static const struct of_device_id sunxi_de2_clk_ids[] = { > + { > + .compatible = "allwinner,sun8i-a83t-de2-clk", > + .data = &sun8i_a83t_de2_clk_desc, > + }, > + { > + .compatible = "allwinner,sun50i-h5-de2-clk", > + .data = &sun50i_a64_de2_clk_desc, > + }, > + /* > + * The Allwinner A64 SoC needs some bit to be poke in syscon to make > + * DE2 really working. > + * So there's currently no A64 compatible here. > + * H5 shares the same reset line with A64, so here H5 is using the > + * clock description of A64. > + */ > + { } > +};
So that A64 driver would require more than just what you defined in the binding in order to operate?
Maxime
-- Maxime Ripard, Free Electrons Embedded Linux and Kernel engineering http://free-electrons.com [unhandled content-type:application/pgp-signature] | |