lkml.org 
[lkml]   [2017]   [Apr]   [10]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH 2/6] scsi: hisi_sas: workaround a SoC SATA IO processing bug
On Mon, Apr 10, 2017 at 09:21:57PM +0800, John Garry wrote:
> From: Xiaofei Tan <tanxiaofei@huawei.com>
>
> This patch provides a workaround a SoC bug where SATA IPTTs for
> different devices may conflict.
>
> The workaround solution requests the following:
> 1. SATA device id must be even and not equal to SAS IPTT.
> 2. SATA device can not share the same IPTT with other SAS or
> SATA device.
>
> Besides we shall consider IPTT value 0 is reserved for another SoC
> bug (STP device open link at firstly after SAS controller reset).
>
> To sum up, the solution is:
> Each SATA device uses independent and continuous 32 even IPTT from
> 64 to 4094, then v2 hw can only support 63 SATA devices.
> All SAS device(SSP/SMP devices) share odd IPTT value from 1 to
> 4095.
>
> Signed-off-by: Xiaofei Tan <tanxiaofei@huawei.com>
> Signed-off-by: John Garry <john.garry@huawei.com>
> ---

Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
--
Johannes Thumshirn Storage
jthumshirn@suse.de +49 911 74053 689
SUSE LINUX GmbH, Maxfeldstr. 5, 90409 Nürnberg
GF: Felix Imendörffer, Jane Smithard, Graham Norton
HRB 21284 (AG Nürnberg)
Key fingerprint = EC38 9CAB C2C4 F25D 8600 D0D0 0393 969D 2D76 0850

\
 
 \ /