Messages in this thread Patch in this message | | | From | Stefan Brüns <> | Subject | [PATCH v1 6/7] iio: adc: ina2xx: Align timestamp with conversion ready flag | Date | Fri, 8 Dec 2017 18:41:51 +0100 |
| |
As the timestamp is no longer (ab-)used to measure the function run time, it can be taken at the correct time, i.e. when the conversion has finished.
Signed-off-by: Stefan Brüns <stefan.bruens@rwth-aachen.de> ---
drivers/iio/adc/ina2xx-adc.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
diff --git a/drivers/iio/adc/ina2xx-adc.c b/drivers/iio/adc/ina2xx-adc.c index 65bd9e69faf2..0a6745e15a5d 100644 --- a/drivers/iio/adc/ina2xx-adc.c +++ b/drivers/iio/adc/ina2xx-adc.c @@ -706,8 +706,6 @@ static int ina2xx_work_buffer(struct iio_dev *indio_dev) s64 time; unsigned int alert; - time = iio_get_time_ns(indio_dev); - /* * Because the timer thread and the chip conversion clock * are asynchronous, the period difference will eventually @@ -736,6 +734,8 @@ static int ina2xx_work_buffer(struct iio_dev *indio_dev) } while (!alert); + time = iio_get_time_ns(indio_dev); + /* * Single register reads: bulk_read will not work with ina226/219 * as there is no auto-increment of the register pointer. -- 2.15.1
| |