Subject[PATCH 3/3] rtc: rx8010: Fix for incorrect return value
Date
The err variable is not being reset after a successful read. Explicitly
reset err variable to account for all return paths.

Reported-by: Jens-Peter Oswald <oswald@lre.de>
Signed-off-by: Akshay Bhat <akshay.bhat@timesys.com>
---
drivers/rtc/rtc-rx8010.c | 2 ++
1 file changed, 2 insertions(+)

diff --git a/drivers/rtc/rtc-rx8010.c b/drivers/rtc/rtc-rx8010.c
index 2e06e5f..1ce2078 100644
--- a/drivers/rtc/rtc-rx8010.c
+++ b/drivers/rtc/rtc-rx8010.c
@@ -223,6 +223,7 @@ static int rx8010_init_client(struct i2c_client *client)
2, ctrl);
if (err != 2)
return err < 0 ? err : -EIO;
+ err = 0;

if (ctrl[0] & RX8010_FLAG_VLF)
dev_warn(&client->dev, "Frequency stop was detected\n");
@@ -261,6 +262,7 @@ static int rx8010_read_alarm(struct device *dev, struct rtc_wkalrm *t)
err = i2c_smbus_read_i2c_block_data(client, RX8010_ALMIN, 3, alarmvals);
if (err != 3)
return err < 0 ? err : -EIO;
+ err = 0;

flagreg = i2c_smbus_read_byte_data(client, RX8010_FLAG);
if (flagreg < 0)
--