Messages in this thread Patch in this message |  | | From | raitosyo@gmail ... | Subject | [PATCH] power: supply: charger-manager: Fix typo in condition | Date | Tue, 21 Nov 2017 13:27:12 +0900 |
| |
From: Ryosuke Saito <raitosyo@gmail.com>
Should be discharging_max_duration_ms, not charging_max_duration_ms.
Signed-off-by: Ryosuke Saito <raitosyo@gmail.com> --- drivers/power/supply/charger-manager.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/power/supply/charger-manager.c b/drivers/power/supply/charger-manager.c index 6502fa7..1de4b44 100644 --- a/drivers/power/supply/charger-manager.c +++ b/drivers/power/supply/charger-manager.c @@ -578,7 +578,7 @@ static int check_charging_duration(struct charger_manager *cm) } else if (is_ext_pwr_online(cm) && !cm->charger_enabled) { duration = curr - cm->charging_end_time; - if (duration > desc->charging_max_duration_ms && + if (duration > desc->discharging_max_duration_ms && is_ext_pwr_online(cm)) { dev_info(cm->dev, "Discharging duration exceed %ums\n", desc->discharging_max_duration_ms); -- 2.9.5
|  |