From
Subject[PATCH 1/3] clocksource/drivers/time-armada-370-xp: Fix the clock reference
Date
From: Gregory CLEMENT <gregory.clement@free-electrons.com>

While converting the init function to return an error, the wrong clock
was get. This lead to wrong clock rate and slow down the kernel. For
example, before the patch a typical boot was around 15s after it was 1
minute slower.

Fixes: 12549e27c63c ("clocksource/drivers/time-armada-370-xp: Convert init function to return error")

Signed-off-by: Gregory CLEMENT <gregory.clement@free-electrons.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Tested-by: Stefan Roese <sr@denx.de>
Tested-by: Ralph Sennhauser <ralph.sennhauser@gmail.com>
---
drivers/clocksource/time-armada-370-xp.c | 1 -
1 file changed, 1 deletion(-)

diff --git a/drivers/clocksource/time-armada-370-xp.c b/drivers/clocksource/time-armada-370-xp.c
index 20ec066..9872992 100644
--- a/drivers/clocksource/time-armada-370-xp.c
+++ b/drivers/clocksource/time-armada-370-xp.c
@@ -357,7 +357,6 @@ static int __init armada_xp_timer_init(struct device_node *np)
struct clk *clk = of_clk_get_by_name(np, "fixed");
int ret;

- clk = of_clk_get(np, 0);
if (IS_ERR(clk)) {
pr_err("Failed to get clock");
return PTR_ERR(clk);
--
1.9.1
\
 
 \ /