lkml.org 
[lkml]   [2016]   [Aug]   [15]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH] power:bq27xxx: 27000/10 read FLAGS register as single
Hi,

On Mon, Jul 18, 2016 at 06:12:09PM +0200, H. Nikolaus Schaller wrote:
> The bq27000 and bq27010 have a single byte FLAGS register.
> Other gauges have 16 bit FLAGS registers.
>
> For reading the FLAGS register it is sufficient to read the single
> register instead of reading RSOC at the next higher address as
> well and then ignore the high byte.
>
> This does not change functionality but optimizes i2c and hdq
> traffic.

Thanks, queued into power-supply's -next branch.

-- Sebastian
[unhandled content-type:application/pgp-signature]
\
 
 \ /
  Last update: 2016-09-17 09:57    [W:0.080 / U:0.916 seconds]