Messages in this thread | | | Subject | Re: [PATCH] spi: s3c64xx: do not disable the clock while configuring the spi | From | Krzysztof Kozlowski <> | Date | Thu, 07 Jul 2016 11:41:49 +0200 |
| |
On 07/07/2016 09:23 AM, Andi Shyti wrote: > When the clock is coming from the cmu it is not required to be > disabled and then re-enabled in order to change the rate. > > Besides, some exynos chipsets (e.g. exynos5433) do not deliver > any to the SFR if one from the pclk ("spi" in this case) or sclk > ("busclk") is disabled. > > Remove the clock disabling/enabling to avoid falling into this > situation. > > Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com> > Signed-off-by: Andi Shyti <andi.shyti@samsung.com> > --- > > Hi, > > This patch has been tested by me and Sylwester on Trats2 > (exynos4412) and tm2(e) (exynos5433) boards, for big data > (which use dma transfer) and small data. > > It also fixes in exynos5433 a synchronus abort caused by the fact > that the pclk (spi) doesn't get delivered if the sclk is disabled > (busclk) > > Thanks, > Andi > > drivers/spi/spi-s3c64xx.c | 8 +------- > 1 file changed, 1 insertion(+), 7 deletions(-)
Reviewed-by: Krzysztof Kozlowski <k.kozlowski@samsung.com>