lkml.org 
[lkml]   [2016]   [Jun]   [20]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
From
Date
SubjectRe: [patch V2 00/20] timer: Refactor the timer wheel
On Mon, Jun 20, 2016 at 6:56 AM, Thomas Gleixner <tglx@linutronix.de> wrote:
>
> 2) Cut off at 37hrs for HZ=1000. We could make this configurable as a 1000HZ
> option so datacenter folks can use this and people who don't care and want
> better batching for power can use the 4ms thingy.


if there really is one user of such long timers... could we possibly
make that one robust against early fire of the timer?

eg rule is: if you set timers > 37 hours, you need to cope with early timer fire

\
 
 \ /
  Last update: 2016-06-20 17:21    [W:0.270 / U:0.320 seconds]