lkml.org 
[lkml]   [2016]   [Jun]   [17]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
    /
    SubjectRe: [PATCH V2 33/63] clocksource/drivers/time-armada-370-xp: Convert init function to return error
    From
    Date

    On 16/06/16 22:26, Daniel Lezcano wrote:
    > The init functions do not return any error. They behave as the following:
    >
    > - panic, thus leading to a kernel crash while another timer may work and
    > make the system boot up correctly
    >
    > or
    >
    > - print an error and let the caller unaware if the state of the system
    >
    > Change that by converting the init functions to return an error conforming
    > to the CLOCKSOURCE_OF_RET prototype.
    >
    > Proper error handling (rollback, errno value) will be changed later case
    > by case, thus this change just return back an error or success in the init
    > function.
    >
    > Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
    > ---
    > drivers/clocksource/tegra20_timer.c | 28 ++++++++++++++++------------
    > 1 file changed, 16 insertions(+), 12 deletions(-)

    The $subject does not appear to match with the driver you are modifying
    here.

    Cheers
    Jon

    --
    nvpublic

    \
     
     \ /
      Last update: 2016-06-17 10:01    [W:4.257 / U:0.024 seconds]