Messages in this thread | | | Subject | Re: [PATCH V2 3/4] clk: max77686: Add DT binding details for PMIC MAX77620 | From | Javier Martinez Canillas <> | Date | Thu, 16 Jun 2016 10:02:18 -0400 |
| |
Hello Laxman,
On 06/16/2016 09:23 AM, Laxman Dewangan wrote: > Maxim has used the same clock IP on multiple PMICs like MAX77686, > MAX77802, MAX77620. Only differences are the number of clocks > from these PMICs like MAX77686 has 3 clocks output, MAX776802 have > two clock output and MAX77620 has one clock output. > > Add clock binding details and DT example for the MAX77620. > > Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com> > CC: Krzysztof Kozlowski <k.kozlowski@samsung.com> > CC: Javier Martinez Canillas <javier@dowhile0.org> > > ---
Reviewed-by: Javier Martinez Canillas <javier@osg.samsung.com>