Hi Krzysztof ,

On 9 May 2016 at 11:49, Krzysztof Kozlowski <k.kozlowski@samsung.com> wrote:
> Include the CPU thermal nodes directly in Odroid XU3-family common DTS
> because it is the only user of it. Keeping it in separate DTSI node does
> not bring benefits because:
> 1. It is not re-usable on other non-fan boards (fan is referenced),
> 2. It won't be re-used on future Odroid XU board because different
> CPU cluster behavior.
>
> Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com>
> ---
> arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi | 103 ---------------------
> arch/arm/boot/dts/exynos5422-odroidxu3-common.dtsi | 94 ++++++++++++++++++-
> 2 files changed, 92 insertions(+), 105 deletions(-)
> delete mode 100644 arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi
>
> diff --git a/arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi b/arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi
> deleted file mode 100644
> index 3e4c4ad96d63..000000000000
> --- a/arch/arm/boot/dts/exynos5422-cpu-thermal.dtsi
> +++ /dev/null
> @@ -1,103 +0,0 @@
> -/*
> - * Device tree sources for Exynos5422 thermal zone
> - *
> - * Copyright (c) 2015 Lukasz Majewski <l.majewski@samsung.com>
> - * Anand Moon <linux.amoon@gmail.com>
> - *
> - * This program is free software; you can redistribute it and/or modify
> - * it under the terms of the GNU General Public License version 2 as
> - * published by the Free Software Foundation.
> - *
> - */
> -
> -#include <dt-bindings/thermal/thermal.h>
> -
> -/ {
> - thermal-zones {
> - cpu0_thermal: cpu0-thermal {
> - thermal-sensors = <&tmu_cpu0 0>;
> - polling-delay-passive = <250>;
> - polling-delay = <0>;
> - trips {
> - cpu_alert0: cpu-alert-0 {
> - temperature = <50000>; /* millicelsius */
> - hysteresis = <5000>; /* millicelsius */
> - type = "active";
> - };
> - cpu_alert1: cpu-alert-1 {
> - temperature = <60000>; /* millicelsius */
> - hysteresis = <5000>; /* millicelsius */
> - type = "active";
> - };
> - cpu_alert2: cpu-alert-2 {
> - temperature = <70000>; /* millicelsius */
> - hysteresis = <5000>; /* millicelsius */
> - type = "active";
> - };
> - cpu_crit0: cpu-crit-0 {
> - temperature = <120000>; /* millicelsius */
> - hysteresis = <0>; /* millicelsius */
> - type = "critical";
> - };
> - /*
> - * Exyunos542x support only 4 trip-points
> - * so for these polling mode is required.
> - * Start polling at temperature level of last
> - * interrupt-driven trip: cpu_alert2
> - */
> - cpu_alert3: cpu-alert-3 {
> - temperature = <70000>; /* millicelsius */
> - hysteresis = <10000>; /* millicelsius */
> - type = "passive";
> - };
> - cpu_alert4: cpu-alert-4 {
> - temperature = <85000>; /* millicelsius */
> - hysteresis = <10000>; /* millicelsius */
> - type = "passive";
> - };
> -
> - };
> - cooling-maps {
> - map0 {
> - trip = <&cpu_alert0>;
> - cooling-device = <&fan0 0 1>;
> - };
> - map1 {
> - trip = <&cpu_alert1>;
> - cooling-device = <&fan0 1 2>;
> - };
> - map2 {
> - trip = <&cpu_alert2>;
> - cooling-device = <&fan0 2 3>;
> - };
> - /*
> - * When reaching cpu_alert3, reduce CPU
> - * by 2 steps. On Exynos5422/5800 that would
> - * be: 1500 MHz and 1100 MHz.
> - */
> - map3 {
> - trip = <&cpu_alert3>;
> - cooling-device = <&cpu0 0 2>;
> - };
> - map4 {
> - trip = <&cpu_alert3>;
> - cooling-device = <&cpu4 0 2>;
> - };
> -
> - /*
> - * When reaching cpu_alert4, reduce CPU
> - * further, down to 600 MHz (11 steps for big,
> - * 7 steps for LITTLE).
> - */
> - map5 {
> - trip = <&cpu_alert4>;
> - cooling-device = <&cpu0 3 7>;
> - };
> - map6 {
> - trip = <&cpu_alert4>;
> - cooling-device = <&cpu4 3 11>;
> - };
> - };
> - };
> - };
> -};
> diff --git a/arch/arm/boot/dts/exynos5422-odroidxu3-common.dtsi b/arch/arm/boot/dts/exynos5422-odroidxu3-common.dtsi
> index 2a4e10bc8801..ff05041835e5 100644
> --- a/arch/arm/boot/dts/exynos5422-odroidxu3-common.dtsi
> +++ b/arch/arm/boot/dts/exynos5422-odroidxu3-common.dtsi
> @@ -1,9 +1,11 @@
> /*
> * Hardkernel Odroid XU3 board device tree source
> *
> - * Copyright (c) 2014 Collabora Ltd.
> * Copyright (c) 2013 Samsung Electronics Co., Ltd.
> * http://www.samsung.com
> + * Copyright (c) 2014 Collabora Ltd.
> + * Copyright (c) 2015 Lukasz Majewski <l.majewski@samsung.com>
> + * Anand Moon <linux.amoon@gmail.com>
> *
> * This program is free software; you can redistribute it and/or modify
> * it under the terms of the GNU General Public License version 2 as
> @@ -16,7 +18,6 @@
> #include <dt-bindings/sound/samsung-i2s.h>
> #include "exynos5800.dtsi"
> #include "exynos5422-cpus.dtsi"
> -#include "exynos5422-cpu-thermal.dtsi"
>
> / {
> memory {
> @@ -54,6 +55,95 @@
> #cooling-cells = <2>;
> cooling-levels = <0 130 170 230>;
> };
> +
> + thermal-zones {
> + cpu0_thermal: cpu0-thermal {
> + thermal-sensors = <&tmu_cpu0 0>;
> + polling-delay-passive = <250>;
> + polling-delay = <0>;
> + trips {
> + cpu_alert0: cpu-alert-0 {
> + temperature = <50000>; /* millicelsius */
> + hysteresis = <5000>; /* millicelsius */
> + type = "active";
> + };
> + cpu_alert1: cpu-alert-1 {
> + temperature = <60000>; /* millicelsius */
> + hysteresis = <5000>; /* millicelsius */
> + type = "active";
> + };
> + cpu_alert2: cpu-alert-2 {
> + temperature = <70000>; /* millicelsius */
> + hysteresis = <5000>; /* millicelsius */
> + type = "active";
> + };
> + cpu_crit0: cpu-crit-0 {
> + temperature = <120000>; /* millicelsius */
> + hysteresis = <0>; /* millicelsius */
> + type = "critical";
> + };
> + /*
> + * Exynos542x supports only 4 trip-points
> + * so for these polling mode is required.
> + * Start polling at temperature level of last
> + * interrupt-driven trip: cpu_alert2
> + */
> + cpu_alert3: cpu-alert-3 {
> + temperature = <70000>; /* millicelsius */
> + hysteresis = <10000>; /* millicelsius */
> + type = "passive";
> + };
> + cpu_alert4: cpu-alert-4 {
> + temperature = <85000>; /* millicelsius */
> + hysteresis = <10000>; /* millicelsius */
> + type = "passive";
> + };
> +
> + };
> + cooling-maps {
> + map0 {
> + trip = <&cpu_alert0>;
> + cooling-device = <&fan0 0 1>;
> + };
> + map1 {
> + trip = <&cpu_alert1>;
> + cooling-device = <&fan0 1 2>;
> + };
> + map2 {
> + trip = <&cpu_alert2>;
> + cooling-device = <&fan0 2 3>;
> + };
> + /*
> + * When reaching cpu_alert3, reduce CPU
> + * by 2 steps. On Exynos5422/5800 that would
> + * be: 1500 MHz and 1100 MHz.
> + */
> + map3 {
> + trip = <&cpu_alert3>;
> + cooling-device = <&cpu0 0 2>;
> + };
> + map4 {
> + trip = <&cpu_alert3>;
> + cooling-device = <&cpu4 0 2>;
> + };
> +
> + /*
> + * When reaching cpu_alert4, reduce CPU
> + * further, down to 600 MHz (11 steps for big,
> + * 7 steps for LITTLE).
> + */
> + map5 {
> + trip = <&cpu_alert4>;
> + cooling-device = <&cpu0 3 7>;
> + };
> + map6 {
> + trip = <&cpu_alert4>;
> + cooling-device = <&cpu4 3 11>;
> + };
> + };
> + };
> + };
> +
> };
>
> &bus_wcore {
> --
> 1.9.1
>

Could you defer this patch, during my testing with pm-qa from linaro.

git://git.linaro.org/tools/pm-qa.git

When their is running of thermal test case cpu usage reaches around
300+ percentage
and some time's the Odroid XU4 hang down.
-------------------------------------------------------------------------
[ 1028.056619] CPU4: shutdown
[ 1148.510372] IRQ54 no longer affine to CPU5
[ 1148.511864] CPU5: shutdown
[ 1268.921073] IRQ55 no longer affine to CPU6
[ 1268.922564] CPU6: shutdown
[ 1389.271930] cpu cpu4: Failed to find opp_table: -19
[ 1389.301668] IRQ56 no longer affine to CPU7
[ 1389.303132] CPU7: shutdown
[ 1510.538424] cpu cpu4: opp_list_debug_create_link: Failed to create link
[ 1510.543762] cpu cpu4: _add_opp_dev: Failed to register opp debugfs (-12)
[ 1510.550625] cpu cpu7: opp_list_debug_create_link: Failed to create link
[ 1510.557037] cpu cpu7: _add_opp_dev: Failed to register opp debugfs (-12)
[ 1510.664649] cpu cpu5: cpufreq_init: failed to get clk: -2
[ 1510.720567] cpu cpu6: cpufreq_init: failed to get clk: -2
[ 1510.788280] cpu cpu7: cpufreq_init: failed to get clk: -2
root@odroidxu4l:/home/odroid/study/linaro/pm-qa# killall heat_cpu

-------------------------------------------------------------------------
And some time I observed that the board will poweroff on reaching
temperature 120 degree C.
when I am compiling the kernel with or above. make -j8
-------------------------------------------------------------------------
root@odroidxu4l:~# * Starting NTP server ntpd [ OK ]
saned disabled; edit /etc/default/saned
[ 4118.924470] thermal thermal_zone3: critical temperature reached(121
C),shutting down
[ 4119.014327] thermal thermal_zone3: critical temperature reached(121
C),shutting down

Broadcast message from root@odroidxu4l
(unknown) at 20:41 ...

The system is going down for power off NOW!

Broadcast message from root@odroidxu4l
(unknown) at 20:41 ...

The system is going down for power off NOW!
[ 4119.431386] thermal thermal_zone3: critical temperature reached(121
C),shutting down
[ 4120.206709] thermal thermal_zone3: critical temperature reached(120
C),shutting down

Broadcast message from root@odroidxu4l
(unknown) at 20:41 ...

The system is going down for power off NOW!
wait-for-state stop/waiting
[ 4157.574406] reboo

U-Boot 2016.03-00665-g563d8d9-dirty (Apr 04 2016 - 22:27:07 +0930) for
ODROID-XU3

CPU: Exynos5422 @ 800 MHz
Model: Odroid XU3 based on EXYNOS5422
Board: Odroid XU3 based on EXYNOS5422
Type: xu4
DRAM: 2 GiB
MMC: EXYNOS DWMMC: 0, EXYNOS DWMMC: 1
*** Warning - bad CRC, using default environment
-------------------------------------------------------------------------
Once the thermal issue is fixed we can redo this changes.

Best Regards
-Anand Moon

\
 
 \ /