Messages in this thread | | | Date | Tue, 8 Mar 2016 13:09:02 -0800 | From | Eduardo Valentin <> | Subject | Re: [PATCH v2] thermal: consistently use int for trip temp |
| |
On Tue, Mar 08, 2016 at 11:24:39AM +0800, Wei Ni wrote: > > > On 2016年03月07日 16:23, Wei Ni wrote: > > There had a build error in previous patch. > > Fixed it in this version. > > Please review it. > > Add CC: linux-pm@vger.kernel.org > > > > > Thanks. > > Wei. > > > > On 2016年03月03日 17:33, Wei Ni wrote: > >> The commit 17e8351a7739 consistently use int for temperature, > >> however it missed a few in trip temperature and thermal_core. > >> > >> In current codes, the trip->temperature used "unsigned long" > >> and zone->temperature used"int", if the temperature is negative > >> value, it will get wrong result when compare temperature with > >> trip temperature. > >> > >> This patch can fix it. > >> > >> Signed-off-by: Wei Ni <wni@nvidia.com>
Rui are you collecting this one?
Acked-by: Eduardo Valentin <edubezval@gmail.com>
| |