Messages in this thread | | | Date | Fri, 4 Mar 2016 22:30:22 -0600 | From | Rob Herring <> | Subject | Re: [PATCH 1/2] regulator: max8973: add DT binding details for junction warn temp |
| |
On Fri, Mar 04, 2016 at 03:57:53PM +0530, Laxman Dewangan wrote: > The driver MAX8973 supports the driver for Maxim MAX77621. > MAX77621 supports the junction temp warning at 120 degC and > 140 degC which is configurable. It generates alert signal when > junction temperature crosses these threshold. > > Add DT properties and its binding details to make this > configuration from DT. > > Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com> > --- > Documentation/devicetree/bindings/regulator/max8973-regulator.txt | 7 +++++++ > 1 file changed, 7 insertions(+)
Acked-by: Rob Herring <robh@kernel.org>
| |