lkml.org 
[lkml]   [2016]   [Oct]   [25]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
SubjectRe: [RFC] shutdown machine when li-ion battery goes below 3V
From
Date
> +	res = bq27xxx_battery_voltage(di, &val);
> + if (res)
> + return res;
> +
> + mV = val.intval / 1000;

Reading that code I stumbled over the comment in
bq27xxx_battery_voltage saying that it returns millivolts. The code
here, the code in bq27xxx_battery_voltage and power_supply.h all
indicate that it in fact returns microvolts. Please double-check and
fix, as it stands now the code looks inconsistent (but not knowing that
device at all I don't feel fit to submit a fix).

regards, Olaf

\
 
 \ /
  Last update: 2016-10-25 21:34    [W:0.044 / U:0.464 seconds]