SubjectRe: [PATCH V2 1/1] serial: 8250_pci: add RS485 for F81504/508/512
On Tue, 28 Jul 2015 11:59:24 +0800, Peter Hung wrote:
> Add RS485 control for Fintek F81504/508/512
>
> F81504/508/512 can control their RTS with H/W mode.
> PCI configuration space for each port is 0x40 + idx * 8 + 7.
>
> When it set with 0x01, it's configured with RS232 mode.
> RTS is controlled by MCR.
>
> When it set with 0x11, it's configured with RS485 mode.
> RTS is controlled by H/W, RTS low with idle & RX, high with TX.
>
> When it set with 0x31, it's configured with RS485 mode.
> RTS is controlled by H/W, RTS high with idle & RX, low with TX.
>
> We will force 0x01 on pci_fintek_setup().
>
> Changelog:
> V2
> 1. change direct bit operation with meaningful define name.
> 2. due to F81504 series only support SER_RS485_ENABLED &
> SER_RS485_RTS_ON_SEND. We'll clean non-support area of
> struct serial_rs485.
> 3. change control method of SER_RS485_RTS_ON_SEND. In our
> reference circuit, the transceiver default mode needed
> in rx mode with RTS logic high, tx mode with RTS logic low.
>
> If user set to SER_RS485_ENABLED(default), we should set
> reg with 0x31. if SER_RS485_ENABLED | SER_RS485_RTS_ON_SEND
> will set reg to 0x11.
>
> Signed-off-by: Peter Hung <hpeter+linux_kernel@gmail.com>

Looks better, thanks. For future postings please put the changelog
below the ---, we don't need it in the logs.


\
 
 \ /
  Last update: 2015-07-29 21:11    [from the cache]