lkml.org 
[lkml]   [2015]   [Jul]   [13]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH 5/6] mfd: devicetree: bindings: 88pm800: Add DT property for dual phase enable
On 13.07.2015 16:50, Vaibhav Hiremath wrote:
>
>
> On Saturday 11 July 2015 12:46 PM, Krzysztof Kozlowski wrote:
>> W dniu 09.07.2015 o 20:47, Vaibhav Hiremath pisze:
>>> 88PM860 family of device supports dual phase mode on BUCK1 supply
>>> providing total 6A capacity.
>>> Note that by default they operate independently with 3A capacity.
>>>
>>> This patch adds the devicetree binding to enable this
>>> feature.
>>>
>>> Signed-off-by: Vaibhav Hiremath <vaibhav.hiremath@linaro.org>
>>> ---
>>> Documentation/devicetree/bindings/mfd/88pm800.txt | 6 ++++++
>>> 1 file changed, 6 insertions(+)
>>>
>>> diff --git a/Documentation/devicetree/bindings/mfd/88pm800.txt
>>> b/Documentation/devicetree/bindings/mfd/88pm800.txt
>>> index ae1311c..c756b31 100644
>>> --- a/Documentation/devicetree/bindings/mfd/88pm800.txt
>>> +++ b/Documentation/devicetree/bindings/mfd/88pm800.txt
>>> @@ -15,6 +15,12 @@ Optional properties :
>>> CLK32K3 - for 88pm800
>>> CLK32K2 - for 88pm860
>>>
>>> + (Applicable only to PXA910 family):
>>> +
>>> + - marvell,88pm860-buck1-dualphase-en : If set, enable dual phase
>>> on BUCK1,
>>> + providing 6A capacity.
>>> + Without this both BUCK1A and BUCK1B operates independently with
>>> 3A capacity.
>>> +
>>
>> 1. How does this relates to regulator driver? The
>> drivers/regulator/88pm800.c defines constraints for regulator which may
>> be contradictory.
>>
>> 2. This looks like a job for regulator driver, not MFD. Then you could
>> use standard regulator bindings (setting maximum current to 6A would
>> change the regulator to different mode).
>
> Make sense. and even better.
>
> I believe you are referring to,
>
> regulator-min-microamp = <3000000>;
> regulator-max-microamp = <6000000>;
>
> And provide set_current_limit() callback, to set the dualphase.
>
> Just to clarify more on this,
>
> The DT property would look something like,
>
> regulators {
> compatible = "marvell,88pm80x-regulator";
>
> buck1a: BUCK1A {
> regulator-compatible = "buck1";
> regulator-min-microvolt = <600000>;
> regulator-max-microvolt = <1800000>;
>
> regulator-min-microamp = <3000000>;
> regulator-max-microamp = <6000000>;
>
> regulator-boot-on;
> regulator-always-on;
> };
>
> buck1b: BUCK1B {
> regulator-compatible = "buck1b";
> regulator-min-microvolt = <600000>;
> regulator-max-microvolt = <1800000>;
>
> regulator-min-microamp = <3000000>;
> regulator-max-microamp = <6000000>;
>
> regulator-boot-on;
> regulator-always-on;
> };
> };
>
>
> And for the platforms, where dual phase is not required,
> we can either choose not to set these properties or set it to
>
>
> regulator-min-microamp = <3000000>;
> regulator-max-microamp = <3000000>;

Yes, exactly. I only wonder if regulator core would support properly
such bindings - setting current limit for a voltage regulator. I didn't
tried this but it should work.

Best regards,
Krzysztof



\
 
 \ /
  Last update: 2015-07-13 10:41    [W:0.360 / U:1.232 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site