Messages in this thread | | | Date | Thu, 09 Apr 2015 12:56:26 +0100 | From | Jonathan Cameron <> | Subject | Re: [PATCH] iio: pressure: bmp280: fix temp compensation |
| |
On 08/04/15 16:30, Vlad Dogaru wrote: > On Wed, Apr 08, 2015 at 06:26:12PM +0300, Irina Tirdea wrote: >> Temperature reads on bmp280 device always return 0, >> due to a missing step in the compensation formula >> (data->tfine is never initialized). >> >> Initialize data->tfine value so we get correct >> temperature and pressure values. >> >> Signed-off-by: Irina Tirdea <irina.tirdea@intel.com> > > Reviewed-by: Vlad Dogaru <vlad.dogaru@intel.com> > > Nice catch, this must have been lost during a refactoring. > > Thanks, > Vlad > Thanks,
Applied to fixes-togreg which is now based on staging-next which gives you an idea of when this will go to Greg now!
| |