lkml.org 
[lkml]   [2015]   [Apr]   [24]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH 2/3] ASoC: tas571x: New driver for TI TAS571x power amplifiers
On Thu, Apr 23, 2015 at 05:47:49PM -0700, Kevin Cernekee wrote:

> This is mostly working OK, but regcache_sync() assumes that the
> hardware registers have been reset back to the default values. The
> "pdn" GPIO doesn't actually reset the state of the tas571x; it just
> makes I2C inaccessible and inhibits audio output. So if the factory
> default for mute is 0, corner cases like this fail:

...

> Aside from unnecessarily pulsing the reset GPIO when transitioning
> back from SND_SOC_BIAS_OFF or overriding regcache_default_sync(), can
> you think of a way to work around this?

Do you need to work around it? If the register map is being perserved
you don't need to sync so just don't do it - it's just that the normal
expectation would be that power down would cause the register map to be
reset.
[unhandled content-type:application/pgp-signature]
\
 
 \ /
  Last update: 2015-04-24 12:01    [W:0.142 / U:1.332 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site