Messages in this thread |  | | Date | Wed, 11 Mar 2015 17:43:21 -0700 | | From | Stephen Boyd <> | | Subject | Re: [PATCH v2] clk: qcom: Properly change rates for ahbix clock |
| |
On 03/06/15 15:41, Stephen Boyd wrote: > The ahbix clock can never be turned off in practice. To change the > rates we need to switch the mux off the M/N counter to an always on > source (XO), reprogram the M/N counter to get the rate we want and > finally switch back to the M/N counter. Add a new ops structure > for this type of clock so that we can set the rate properly. > > Fixes: c99e515a92e9 "clk: qcom: Add IPQ806X LPASS clock controller (LCC) driver" > Cc: Kenneth Westfield <kwestfie@codeaurora.org> > Signed-off-by: Stephen Boyd <sboyd@codeaurora.org> > --- > >
Applied to clk-next
-- Qualcomm Innovation Center, Inc. is a member of Code Aurora Forum, a Linux Foundation Collaborative Project
|  |