Messages in this thread Patch in this message | | | From | Peter Ujfalusi <> | Subject | [PATCH 2/2] ARM: DRA7: hwmod_data: Change locked_class for atl hwmod | Date | Fri, 6 Feb 2015 14:48:36 +0200 |
| |
The ATL hwmod can be used in nested way when it is selected to be the functional clock for McASP. For this lockdep validator will trigger false positive warning. By assigning separate class to atl locking will sort this out.
Signed-off-by: Peter Ujfalusi <peter.ujfalusi@ti.com> --- arch/arm/mach-omap2/omap_hwmod_7xx_data.c | 1 + 1 file changed, 1 insertion(+)
diff --git a/arch/arm/mach-omap2/omap_hwmod_7xx_data.c b/arch/arm/mach-omap2/omap_hwmod_7xx_data.c index e8692e7675b8..87f259e8c574 100644 --- a/arch/arm/mach-omap2/omap_hwmod_7xx_data.c +++ b/arch/arm/mach-omap2/omap_hwmod_7xx_data.c @@ -185,6 +185,7 @@ static struct omap_hwmod dra7xx_atl_hwmod = { .class = &dra7xx_atl_hwmod_class, .clkdm_name = "atl_clkdm", .main_clk = "atl_gfclk_mux", + .lockdep_class = HWMOD_LOCKDEP_SUBCLASS_CLASS1, .prcm = { .omap4 = { .clkctrl_offs = DRA7XX_CM_ATL_ATL_CLKCTRL_OFFSET, -- 2.2.2
| |