lkml.org 
[lkml]   [2015]   [Oct]   [7]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
Patch in this message
/
From
Subject[PATCH v2] iio: mxs-lradc: Fix temperature offset
Date
0° Kelvin is actually −273.15°C, not -272.15°C. Fix the temperature offset.
Also improve the comment explaining the calculation.

Reported-by: Janusz Użycki <j.uzycki@elpromaelectronics.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
---
drivers/staging/iio/adc/mxs-lradc.c | 9 +++++----
1 file changed, 5 insertions(+), 4 deletions(-)

diff --git a/drivers/staging/iio/adc/mxs-lradc.c b/drivers/staging/iio/adc/mxs-lradc.c
index 3f7715c9968b..47fc00a3f63b 100644
--- a/drivers/staging/iio/adc/mxs-lradc.c
+++ b/drivers/staging/iio/adc/mxs-lradc.c
@@ -915,11 +915,12 @@ static int mxs_lradc_read_raw(struct iio_dev *iio_dev,
case IIO_CHAN_INFO_OFFSET:
if (chan->type == IIO_TEMP) {
/* The calculated value from the ADC is in Kelvin, we
- * want Celsius for hwmon so the offset is
- * -272.15 * scale
+ * want Celsius for hwmon so the offset is -273.15
+ * The offset is applied before scaling so it is
+ * actually -213.15 * 4 / 1.012 = -1079.644268
*/
- *val = -1075;
- *val2 = 691699;
+ *val = -1079;
+ *val2 = 644268;

return IIO_VAL_INT_PLUS_MICRO;
}
--
2.1.4


\
 
 \ /
  Last update: 2015-10-07 13:41    [W:0.048 / U:0.136 seconds]