Subject[PATCH] regulator: palmas: Remove wrong comment for the equation calculating num_voltages
From
Date
Current equation on the comment is wrong.
For linear mapping starting from 0, the equation is (maxV-minV)/stepV + 1.
Since the linear mapping for PALMAS is not all starting from 0, the equation
on the comment is not useful and misleading. Thus remove it.

Signed-off-by: Axel Lin <axel.lin@ingics.com>
---
drivers/regulator/palmas-regulator.c | 6 ------
1 file changed, 6 deletions(-)

diff --git a/drivers/regulator/palmas-regulator.c b/drivers/regulator/palmas-regulator.c
index fba4faa..7e2b165 100644
--- a/drivers/regulator/palmas-regulator.c
+++ b/drivers/regulator/palmas-regulator.c
@@ -201,12 +201,6 @@ static unsigned int palmas_smps_ramp_delay[4] = {0, 10000, 5000, 2500};
#define SMPS_CTRL_MODE_ECO 0x02
#define SMPS_CTRL_MODE_PWM 0x03

-/* These values are derived from the data sheet. And are the number of steps
- * where there is a voltage change, the ranges at beginning and end of register
- * max/min values where there are no change are ommitted.
- *
- * So they are basically (maxV-minV)/stepV
- */
#define PALMAS_SMPS_NUM_VOLTAGES 122
#define PALMAS_SMPS10_NUM_VOLTAGES 2
#define PALMAS_LDO_NUM_VOLTAGES 50
--
1.8.1.2




\
 
 \ /