Hi Uwe,
On Fri, Jun 28, 2013 at 4:30 AM, Uwe Kleine-König <u.kleine-koenig@pengutronix.de> wrote: > On Fri, Jun 28, 2013 at 12:32:05AM -0300, Fabio Estevam wrote: >> From: Fabio Estevam <fabio.estevam@freescale.com> >> >> Later in ipu_dp_get() the index of the flow array is calculated by: >> flow >> 1 >> >> So adjust its maximum to IPUV3_NUM_FLOWS << 1. > Maybe squash this into patch 4?
Patch 4 is just cosmetic, but in this one I am changing the comparison from: 'if (flow > 5)' to 'if (flow > 6)'
,so that's why I splitted them.
I am OK with squashing the two patches together though.
Sascha,
Do you agree with the 'if (flow > 6)' change?
Thanks,