lkml.org 
[lkml]   [2013]   [Mar]   [11]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH 4/8] memory: emif: Handle devices which are not rated for >85C
On Monday 11 March 2013 10:36 AM, Lokesh Vutla wrote:
> From: Nishanth Menon <nm@ti.com>
>
> As per JESD209-2E specification for LPDDR2,
> http://www.jedec.org/standards-documents/results/jesd209-2E
> Table 73, LPDDR2 memories come in two flavors - Standard and
> Extended. The Standard types can operate from -25C to +85C
> However, beyond that and upto +105C can only be supported by
> Extended types.
>
right.

> Unfortunately, it seems there is no info in MR0(device info) or
> MR[1,2](device feature) for run time detection of this capability
> as far as seen on the spec. Hence, we provide a custom_config
> flag to be populated by platforms which have these "extended"
> type memories.
>
> For the "Standard" memories, we need to consider MR4 notifications
> of temperature triggers >85C as equivalent to thermal shutdown
> events (equivalent to Spec specified thermal shutdown events for
> "extended" parts).
>
Make sense.

> Reported-by: Richard Woodruff <r-woodruff2@ti.com>
> Signed-off-by: Nishanth Menon <nm@ti.com>
> Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
> ---
Thanks for the fix.
Acked-by: Santosh Shilimkar <santosh.shilimkar@ti.com>



\
 
 \ /
  Last update: 2013-03-11 07:21    [W:0.161 / U:1.032 seconds]