On Thu, Nov 01, 2012 at 11:47:52PM +0000, Luck, Tony wrote: > > Right, but at least in the csrow case, we still can compute back the > > csrow even with the interleaving, after we know how it is done exactly > > (on which address bits, etc). I think this should be doable on Intel > > controllers too but I don't know. > > No. Architecturally all Intel provides is the physical address in MCi_ADDR. > To do anything with that you are into per-system space, and the > registers that define the mappings are not necessarily available > to OS code ... sometimes they are, and sometimes they are even > documented in places where Mauro can use them to write an > EDAC driver ... but there are no guarantees.
One more reason that we need some sort of tables telling us which rank/csrow maps to which DIMM and thus silkscreen label so that we can be able to say the following from software:
"You just had a single corrected ECC error in the DIMM with label P0_DIMM_A"
or whatever unique naming each platform vendor comes up with.
The day hw people give me this, I'm going to throw a big party and invite all LKML.