Messages in this thread Patch in this message | | | From | Linus Walleij <> | Subject | [PATCH 7/8] mfd/db8500-prcmu: remove check for firmware bug | Date | Fri, 13 Jan 2012 16:20:51 +0100 |
| |
From: Jonas Aaberg <jonas.aberg@stericsson.com>
In prcmu firmware version 3.4.4 the issue with longer intervalls than 131 s was fixed, we don't expect the issue to creep back up.
Signed-off-by: Jonas Aaberg <jonas.aberg@stericsson.com> Signed-off-by: Linus Walleij <linus.walleij@linaro.org> --- drivers/mfd/db8500-prcmu.c | 8 -------- 1 files changed, 0 insertions(+), 8 deletions(-)
diff --git a/drivers/mfd/db8500-prcmu.c b/drivers/mfd/db8500-prcmu.c index 8056968..0ee8015 100644 --- a/drivers/mfd/db8500-prcmu.c +++ b/drivers/mfd/db8500-prcmu.c @@ -2184,16 +2184,8 @@ int db8500_prcmu_kick_a9wdog(u8 id) /* * timeout is 28 bit, in ms. */ -#define MAX_WATCHDOG_TIMEOUT 131000 int db8500_prcmu_load_a9wdog(u8 id, u32 timeout) { - if (timeout > MAX_WATCHDOG_TIMEOUT) - /* - * Due to calculation bug in prcmu fw, timeouts - * can't be bigger than 131 seconds. - */ - return -EINVAL; - return prcmu_a9wdog(MB4H_A9WDOG_LOAD, (id & A9WDOG_ID_MASK) | /* -- 1.7.8
| |