On 07/27/2011 11:19 PM, Andrew Morton wrote: > On Mon, 11 Jul 2011 12:57:46 +0200 > Daniel Gl__ckner <dg@emlix.com> wrote: > >> As the comment explains, the intention of the code is to clear the >> OMAP_RTC_CTRL_MODE_12_24 bit, but instead it only clears the >> OMAP_RTC_CTRL_SPLIT and OMAP_RTC_CTRL_AUTO_COMP bits, which should be >> kept. OMAP_RTC_CTRL_DISABLE, OMAP_RTC_CTRL_SET_32_COUNTER, >> OMAP_RTC_CTRL_TEST, and OMAP_RTC_CTRL_ROUND_30S are also better off >> being cleared.
> What were the user-visible effects of the bug?
The contents of the control register is undefined after a complete power loss. On our board the RTC has been observed to sometimes power up with the OMAP_RTC_CTRL_SET_32_COUNTER bit being set, which stops the clock.