Messages in this thread Patch in this message | | | From | Phil Oester <> | Subject | [PATCH] Fix embedded nic order on Dell PowerEdge systems | Date | Wed, 8 Jun 2011 13:14:13 -0700 |
| |
In commit 6e8af08dfa40b747002207d3ce8e8b43a050d99f ("PCI: enable pci=bfsort by default on future Dell systems"), the callback added was placed at the top of the list, before the specific PowerEdge models. This ends up breaking the more specific models listed, since the new callback handles all Dell systems but the older systems don't have the new 0xB1 smbios entry.
Fix this by placing the new check _after_ the more specific PowerEdge sytems.
Phil Oester
Signed-off-by: Phil Oester <kernel@linuxace.com>
diff --git a/arch/x86/pci/common.c b/arch/x86/pci/common.c index 5fe7502..92df322 100644 --- a/arch/x86/pci/common.c +++ b/arch/x86/pci/common.c @@ -247,13 +247,6 @@ static const struct dmi_system_id __devinitconst pciprobe_dmi_table[] = { }, #endif /* __i386__ */ { - .callback = find_sort_method, - .ident = "Dell System", - .matches = { - DMI_MATCH(DMI_SYS_VENDOR, "Dell Inc"), - }, - }, - { .callback = set_bf_sort, .ident = "Dell PowerEdge 1950", .matches = { @@ -294,6 +287,13 @@ static const struct dmi_system_id __devinitconst pciprobe_dmi_table[] = { }, }, { + .callback = find_sort_method, + .ident = "Dell System", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "Dell Inc"), + }, + }, + { .callback = set_bf_sort, .ident = "HP ProLiant BL20p G3", .matches = {
| |