Messages in this thread | | | Date | Tue, 06 Dec 2011 12:24:06 +0530 | From | Rajendra Nayak <> | Subject | Re: [PATCH v5 1/4] regulator: helper routine to extract regulator_init_data |
| |
On Monday 05 December 2011 04:27 PM, Mark Brown wrote: > On Mon, Dec 05, 2011 at 04:14:40PM +0530, Thomas Abraham wrote: >> On 5 December 2011 16:04, Mark Brown > >>> With the regulator device tree bindings if the regulator is configured >>> to run a single voltage the bindings will set apply_uV unconditionally >>> so there's no need for a separate constraint. > >> Sorry if I have missed this, but I could not find 'apply_uV' being set >> as you described in the v5 of the regulator-dt patchset. > > Yes, looks like Rajendra missed that - just fixed it.
Thanks Mark, I certainly seem to have missed it.
| |