Messages in this thread
    /
    Date
    SubjectRe: [PATCH v5 1/4] regulator: helper routine to extract regulator_init_data
    From
    On 5 December 2011 16:04, Mark Brown
    <broonie@opensource.wolfsonmicro.com> wrote:
    > On Mon, Dec 05, 2011 at 02:40:50PM +0530, Thomas Abraham wrote:
    >> On 4 December 2011 21:24, Mark Brown
    >
    >> > If the regulator isn't software managed then always_on covers this - the
    >> > regulator core will enable any always_on regulators that haven't been
    >> > enabled already.
    >
    >> Thanks for the hint. I was trying to deal with a regulator that was
    >> not software managed but also required the voltage level to be set to
    >> certain level. That was possible with 'apply_uV' constraint in non-dt
    >> case. Anyway, I have modified the code to manage the regulator and
    >> this works fine in dt case as well without the 'apply_uV' constraint.
    >
    > With the regulator device tree bindings if the regulator is configured
    > to run a single voltage the bindings will set apply_uV unconditionally
    > so there's no need for a separate constraint.
    >

    Sorry if I have missed this, but I could not find 'apply_uV' being set
    as you described in the v5 of the regulator-dt patchset.

    Thanks,
    Thomas.


    \
     
     \ /