lkml.org 
[lkml]   [2011]   [Nov]   [17]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
    Patch in this message
    /
    From
    Subject[RFC PATCH 2/2] power: Charger-Manager: add properties for power-supply-class
    Date
    Charger Manager provides power-supply-class aggregating
    information from multiple chargers and a fuel-gauge.

    Signed-off-by: Donggeun Kim <dg77.kim@samsung.com>
    Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
    Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
    ---
    Documentation/power/charger-manager.txt | 14 ++
    drivers/power/charger-manager.c | 295 ++++++++++++++++++++++++++++++-
    include/linux/power/charger-manager.h | 17 ++
    3 files changed, 325 insertions(+), 1 deletions(-)

    diff --git a/Documentation/power/charger-manager.txt b/Documentation/power/charger-manager.txt
    index 99630e5..3a55c79 100644
    --- a/Documentation/power/charger-manager.txt
    +++ b/Documentation/power/charger-manager.txt
    @@ -98,6 +98,11 @@ battery), an instance of Charger Manager is attached to it.

    struct charger_desc {

    +char *psy_name;
    + : The power-supply-class name of the battery. Default is
    + "battery" if psy_name is NULL. Users can access the psy entries
    + at "/sys/class/power_supply/[psy_name]/".
    +
    enum polling_modes polling_mode;
    : CM_POLL_DISABLE: do not poll this battery.
    CM_POLL_ALWAYS: always poll this battery.
    @@ -106,6 +111,12 @@ enum polling_modes polling_mode;
    CM_POLL_CHARGING_ONLY: poll this battery if and only if the
    battery is being charged.

    +unsigned int fullbatt_uV;
    + : If specified with a non-zero value, Charger Manager assumes
    + that the battery is full (capacity = 100) if the battery is not being
    + charged and the battery voltage is equal to or greater than
    + fullbatt_uV.
    +
    unsigned int polling_interval_ms;
    : Required polling interval in ms. Charger Manager will poll
    this battery every polling_interval_ms or more frequently.
    @@ -131,10 +142,13 @@ char *psy_fuel_gauge;
    : Power-supply-class name of the fuel gauge.

    int (*is_temperature_error)(int *mC);
    +bool measure_battery_temp;
    : This callback returns 0 if the temperature is safe for charging,
    a positive number if it is too hot to charge, and a negative number
    if it is too cold to charge. With the variable mC, the callback returns
    the temperature in 1/1000 of centigrade.
    + The source of temperature can be battery or ambient one according to
    + the value of measure_battery_temp.
    };

    5. Other Considerations
    diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c
    index 5006756..818f890 100644
    --- a/drivers/power/charger-manager.c
    +++ b/drivers/power/charger-manager.c
    @@ -118,6 +118,32 @@ static bool is_ext_pwr_online(struct charger_manager *cm)
    }

    /**
    + * get_batt_uV - Get the voltage level of the battery
    + * @cm: the Charger Manager representing the battery.
    + * @uV: the voltage level returned.
    + *
    + * Returns 0 if there is no error.
    + * Returns a negative value on error.
    + */
    +static int get_batt_uV(struct charger_manager *cm, int *uV)
    +{
    + union power_supply_propval val;
    + int ret;
    +
    + if (cm->fuel_gauge)
    + ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
    + POWER_SUPPLY_PROP_VOLTAGE_NOW, &val);
    + else
    + return -ENODEV;
    +
    + if (ret)
    + return ret;
    +
    + *uV = val.intval;
    + return 0;
    +}
    +
    +/**
    * is_charging - Returns true if the battery is being charged.
    * @cm: the Charger Manager representing the battery.
    */
    @@ -369,6 +395,208 @@ static bool cm_monitor(void)
    return stop;
    }

    +static int charger_get_property(struct power_supply *psy,
    + enum power_supply_property psp,
    + union power_supply_propval *val)
    +{
    + struct charger_manager *cm = container_of(psy,
    + struct charger_manager, charger_psy);
    + struct charger_desc *desc = cm->desc;
    + int i, ret = 0, uV;
    +
    + switch (psp) {
    + case POWER_SUPPLY_PROP_STATUS:
    + if (is_charging(cm))
    + val->intval = POWER_SUPPLY_STATUS_CHARGING;
    + else if (is_ext_pwr_online(cm))
    + val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
    + else
    + val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
    + break;
    + case POWER_SUPPLY_PROP_HEALTH:
    + if (cm->emergency_stop > 0)
    + val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
    + else if (cm->emergency_stop < 0)
    + val->intval = POWER_SUPPLY_HEALTH_COLD;
    + else
    + val->intval = POWER_SUPPLY_HEALTH_GOOD;
    + break;
    + case POWER_SUPPLY_PROP_PRESENT:
    + if (is_batt_present(cm))
    + val->intval = 1;
    + else
    + val->intval = 0;
    + break;
    + case POWER_SUPPLY_PROP_VOLTAGE_NOW:
    + ret = get_batt_uV(cm, &i);
    + val->intval = i;
    + break;
    + case POWER_SUPPLY_PROP_CURRENT_NOW:
    + ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
    + POWER_SUPPLY_PROP_CURRENT_NOW, val);
    + break;
    + case POWER_SUPPLY_PROP_TEMP:
    + /* in thenth of centigrade */
    + if (cm->last_temp_mC == INT_MIN)
    + desc->is_temperature_error(&cm->last_temp_mC);
    + val->intval = cm->last_temp_mC / 100;
    + if (!desc->measure_battery_temp)
    + ret = -ENODEV;
    + break;
    + case POWER_SUPPLY_PROP_TEMP_AMBIENT:
    + /* in thenth of centigrade */
    + if (cm->last_temp_mC == INT_MIN)
    + desc->is_temperature_error(&cm->last_temp_mC);
    + val->intval = cm->last_temp_mC / 100;
    + if (desc->measure_battery_temp)
    + ret = -ENODEV;
    + break;
    + case POWER_SUPPLY_PROP_CAPACITY:
    + if (!cm->fuel_gauge) {
    + ret = -ENODEV;
    + break;
    + }
    +
    + if (!is_batt_present(cm)) {
    + /* There is no battery. Assume 100% */
    + val->intval = 100;
    + break;
    + }
    +
    + ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
    + POWER_SUPPLY_PROP_CAPACITY, val);
    + if (ret)
    + break;
    +
    + if (val->intval > 100) {
    + val->intval = 100;
    + break;
    + }
    + if (val->intval < 0)
    + val->intval = 0;
    +
    + /* Do not adjust SOC when charging: voltage is overrated */
    + if (is_charging(cm))
    + break;
    +
    + /*
    + * If the capacity value is inconsistent, calibrate it base on
    + * the battery voltage values and the thresholds given as desc
    + */
    + ret = get_batt_uV(cm, &uV);
    + if (ret) {
    + /* Voltage information not available. No calibration */
    + ret = 0;
    + break;
    + }
    +
    + if (desc->fullbatt_uV > 0 && uV >= desc->fullbatt_uV &&
    + !is_charging(cm)) {
    + val->intval = 100;
    + break;
    + }
    +
    + break;
    + case POWER_SUPPLY_PROP_ONLINE:
    + if (is_ext_pwr_online(cm))
    + val->intval = 1;
    + else
    + val->intval = 0;
    + break;
    + case POWER_SUPPLY_PROP_CHARGE_FULL:
    + if (cm->fuel_gauge) {
    + if (cm->fuel_gauge->get_property(cm->fuel_gauge,
    + POWER_SUPPLY_PROP_CHARGE_FULL, val) == 0)
    + break;
    + }
    +
    + if (is_ext_pwr_online(cm)) {
    + /* Not full if it's charging. */
    + if (is_charging(cm)) {
    + val->intval = 0;
    + break;
    + }
    + /*
    + * Full if it's powered but not charging andi
    + * not forced stop by emergency
    + */
    + if (!cm->emergency_stop) {
    + val->intval = 1;
    + break;
    + }
    + }
    +
    + /* Full if it's over the fullbatt voltage */
    + ret = get_batt_uV(cm, &uV);
    + if (!ret && desc->fullbatt_uV > 0 && uV >= desc->fullbatt_uV &&
    + !is_charging(cm)) {
    + val->intval = 1;
    + break;
    + }
    +
    + /* Full if the cap is 100 */
    + if (cm->fuel_gauge) {
    + ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
    + POWER_SUPPLY_PROP_CAPACITY, val);
    + if (!ret && val->intval >= 100 && !is_charging(cm)) {
    + val->intval = 1;
    + break;
    + }
    + }
    +
    + val->intval = 0;
    + ret = 0;
    + break;
    + case POWER_SUPPLY_PROP_CHARGE_NOW:
    + if (is_charging(cm)) {
    + ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
    + POWER_SUPPLY_PROP_CHARGE_NOW,
    + val);
    + if (ret) {
    + val->intval = 1;
    + ret = 0;
    + } else {
    + /* If CHARGE_NOW is supplied, use it */
    + val->intval = (val->intval > 0) ?
    + val->intval : 1;
    + }
    + } else {
    + val->intval = 0;
    + }
    + break;
    + default:
    + return -EINVAL;
    + }
    + return ret;
    +}
    +
    +#define NUM_CHARGER_PSY_OPTIONAL (4)
    +static enum power_supply_property default_charger_props[] = {
    + /* Guaranteed to provide */
    + POWER_SUPPLY_PROP_STATUS,
    + POWER_SUPPLY_PROP_HEALTH,
    + POWER_SUPPLY_PROP_PRESENT,
    + POWER_SUPPLY_PROP_VOLTAGE_NOW,
    + POWER_SUPPLY_PROP_CAPACITY,
    + POWER_SUPPLY_PROP_ONLINE,
    + POWER_SUPPLY_PROP_CHARGE_FULL,
    + /*
    + * Optional properties are:
    + * POWER_SUPPLY_PROP_CHARGE_NOW,
    + * POWER_SUPPLY_PROP_CURRENT_NOW,
    + * POWER_SUPPLY_PROP_TEMP, and
    + * POWER_SUPPLY_PROP_TEMP_AMBIENT,
    + */
    +};
    +
    +static struct power_supply psy_default = {
    + .name = "battery",
    + .type = POWER_SUPPLY_TYPE_BATTERY,
    + .properties = default_charger_props,
    + .num_properties = ARRAY_SIZE(default_charger_props),
    + .get_property = charger_get_property,
    +};
    +
    /**
    * cm_setup_timer - For in-suspend monitoring setup wakeup alarm
    * for suspend_again.
    @@ -536,6 +764,7 @@ static int charger_manager_probe(struct platform_device *pdev)
    struct charger_desc *desc = dev_get_platdata(&pdev->dev);
    struct charger_manager *cm;
    int ret = 0, i;
    + union power_supply_propval val;

    if (g_desc && !rtc_dev && g_desc->rtc) {
    rtc_dev = rtc_class_open(g_desc->rtc);
    @@ -630,10 +859,67 @@ static int charger_manager_probe(struct platform_device *pdev)

    platform_set_drvdata(pdev, cm);

    + memcpy(&cm->charger_psy, &psy_default,
    + sizeof(psy_default));
    + if (!desc->psy_name) {
    + strncpy(cm->psy_name_buf, psy_default.name,
    + PSY_NAME_MAX);
    + } else {
    + strncpy(cm->psy_name_buf, desc->psy_name, PSY_NAME_MAX);
    + }
    + cm->charger_psy.name = cm->psy_name_buf;
    +
    + /* Allocate for psy properties because they may vary */
    + cm->charger_psy.properties = kzalloc(sizeof(enum power_supply_property)
    + * (ARRAY_SIZE(default_charger_props) +
    + NUM_CHARGER_PSY_OPTIONAL),
    + GFP_KERNEL);
    + if (!cm->charger_psy.properties) {
    + dev_err(&pdev->dev, "Cannot allocate for psy properties.\n");
    + ret = -ENOMEM;
    + goto err_chg_stat;
    + }
    + memcpy(cm->charger_psy.properties, default_charger_props,
    + sizeof(enum power_supply_property) *
    + ARRAY_SIZE(default_charger_props));
    + cm->charger_psy.num_properties = psy_default.num_properties;
    +
    + /* Find which optional psy-properties are available */
    + if (!cm->fuel_gauge->get_property(cm->fuel_gauge,
    + POWER_SUPPLY_PROP_CHARGE_NOW, &val)) {
    + cm->charger_psy.properties[cm->charger_psy.num_properties] =
    + POWER_SUPPLY_PROP_CHARGE_NOW;
    + cm->charger_psy.num_properties++;
    + }
    + if (!cm->fuel_gauge->get_property(cm->fuel_gauge,
    + POWER_SUPPLY_PROP_CURRENT_NOW,
    + &val)) {
    + cm->charger_psy.properties[cm->charger_psy.num_properties] =
    + POWER_SUPPLY_PROP_CURRENT_NOW;
    + cm->charger_psy.num_properties++;
    + }
    + if (!desc->measure_battery_temp) {
    + cm->charger_psy.properties[cm->charger_psy.num_properties] =
    + POWER_SUPPLY_PROP_TEMP_AMBIENT;
    + cm->charger_psy.num_properties++;
    + }
    + if (desc->measure_battery_temp) {
    + cm->charger_psy.properties[cm->charger_psy.num_properties] =
    + POWER_SUPPLY_PROP_TEMP;
    + cm->charger_psy.num_properties++;
    + }
    +
    + ret = power_supply_register(NULL, &cm->charger_psy);
    + if (ret) {
    + dev_err(&pdev->dev, "Cannot register charger-manager with"
    + " name \"%s\".\n", cm->charger_psy.name);
    + goto err_register;
    + }
    +
    ret = try_charger_enable(cm, true);
    if (ret) {
    dev_err(&pdev->dev, "Cannot enable charger regulators\n");
    - goto err_chg_stat;
    + goto err_enable;
    }

    /* Add to the list */
    @@ -643,6 +929,10 @@ static int charger_manager_probe(struct platform_device *pdev)

    return 0;

    +err_enable:
    + power_supply_unregister(&cm->charger_psy);
    +err_register:
    + kfree(cm->charger_psy.properties);
    err_chg_stat:
    kfree(cm->charger_stat);
    err_no_charger_stat:
    @@ -665,6 +955,9 @@ static int __devexit charger_manager_remove(struct platform_device *pdev)
    list_del(&cm->entry);
    mutex_unlock(&cm_list_mtx);

    + power_supply_unregister(&cm->charger_psy);
    +
    + kfree(cm->charger_psy.properties);
    kfree(cm->charger_stat);
    if (desc->charger_regulators)
    regulator_bulk_free(desc->num_charger_regulators,
    diff --git a/include/linux/power/charger-manager.h b/include/linux/power/charger-manager.h
    index c91e208..3bc0e34 100644
    --- a/include/linux/power/charger-manager.h
    +++ b/include/linux/power/charger-manager.h
    @@ -48,8 +48,12 @@ struct charger_global_desc {

    /**
    * struct charger_desc
    + * @psy_name: the name of power-supply-class for charger manager
    * @polling_mode:
    * Determine which polling mode will be used
    + * @fullbatt_uV: voltage in microvolt
    + * If it is not being charged and VBATT >= fullbatt_uV,
    + * it is assumed to be full.
    * @polling_interval_ms: interval in millisecond at which
    * charger manager will monitor battery health
    * @battery_present:
    @@ -63,11 +67,18 @@ struct charger_global_desc {
    * return_value > 0: overheat
    * return_value == 0: normal
    * return_value < 0: cold
    + * @measure_battery_temp:
    + * true: measure battery temperature
    + * false: measure ambient temperature
    */
    struct charger_desc {
    + char *psy_name;
    +
    enum polling_modes polling_mode;
    unsigned int polling_interval_ms;

    + unsigned int fullbatt_uV;
    +
    enum data_source battery_present;

    char **psy_charger_stat;
    @@ -78,6 +89,7 @@ struct charger_desc {
    char *psy_fuel_gauge;

    int (*is_temperature_error)(int *mC);
    + bool measure_battery_temp;
    };

    #define PSY_NAME_MAX 30
    @@ -93,6 +105,8 @@ struct charger_desc {
    * @emergency_stop:
    * When setting true, stop charging
    * @last_temp_mC: the measured temperature in milli-Celsius
    + * @psy_name_buf: the name of power-supply-class for charger manager
    + * @charger_psy: power_supply for charger manager
    * @status_save_ext_pwr_inserted:
    * saved status of external power before entering suspend-to-RAM
    * @status_save_batt:
    @@ -111,6 +125,9 @@ struct charger_manager {
    int emergency_stop;
    int last_temp_mC;

    + char psy_name_buf[PSY_NAME_MAX + 1];
    + struct power_supply charger_psy;
    +
    bool status_save_ext_pwr_inserted;
    bool status_save_batt;
    };
    --
    1.7.4.1


    \
     
     \ /
      Last update: 2011-11-17 11:17    [W:0.062 / U:28.864 seconds]