Messages in this thread
/
Date
SubjectRe: [PATCH resend] ab3100: fix off-by-one value range checking for voltage selector
From
2010/7/26 Axel Lin <axel.lin@gmail.com>:

> We use voltage selector as an array index for typ_voltages.
> Thus the valid range for voltage selector should be 0..voltages_len-1.
>
> Signed-off-by: Axel Lin <axel.lin@gmail.com>
> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>

Acked-by: Linus Walleij <linus.walleij@stericsson.com>

Yours,
Linus Walleij


\
 
 \ /