Messages in this thread | | | Date | Mon, 19 Apr 2010 16:56:31 +0100 | From | Ralf Baechle <> | Subject | Re: [PATCH/RESEND] MIPS: Fix sibyte watchdog initialization |
| |
On Mon, Apr 19, 2010 at 08:37:11AM -0700, Guenter Roeck wrote:
> Watchdog configuration register and timer count register were interchanged, > causing wrong values to be written into both registers. > This caused watchdog triggered resets even if the watchdog was reset in time. > > Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> > --- > Resend: > Widening the audience. > Please let me know if there are any problems with this patch.
For the new audience, this patch has been previously posted to linux-mips a few days ago and assuming there are no objections I'd like to merge it upstream for 2.6.34, so an Ack would by nice.
Ralf
| |